岩通多功能電表(IWATSU)
- VOAC7523/22/20/21A
高分解度 509999
最高速度 100次/秒 顯示達50999
强大的运算功能
雙顯示(Dual Display)
雙功能(Dual Function)
隔離通道CH-B的DC V输入(VOAC7520/23)
4端子/2端子電阻測量(VOAC7522/21A)
低價格/高功能
電流高達10A
規格:
1. Typical Sample Rate and Resolution |
|
Sample Rate |
Resolution |
Reading Rate |
Hum Rejection |
SLOW |
5.5-digit |
approx. 4 times/sec |
Yes |
MID |
5.5-digit |
approx. 20 times/sec |
Yes |
FAST |
4.5-digit |
approx. 100 times/sec |
N/A |
|
|
2. DC Volt (DCV) 50mV range is for the VOAC7523/7522 only. |
|
Range |
Resolution |
Input Resistance |
Accuracy* |
5.5-digit |
4.5-digit |
SLOW/MID |
FAST |
50mV |
0.1µV |
1µV |
100MW or more |
0.025+10 |
0.025+15 |
500mV |
1µV |
10µV |
1000MW or more |
0.012+5 |
0.012+10 |
5V |
10µV |
100µV |
0.012+2 |
0.012+7 |
50V |
100µV |
1mV |
approx. 10MW |
0.016+5 |
0.016+10 |
500V |
1mV |
10mV |
0.016+2 |
0.016+7 |
1000V |
10mV |
100mV |
|
The accuracy in the 50mV and 500mV ranges is specified after zero compensation through the REL operation. |
Sample rate in the 50mV range
SLOW/MID: Approx. 0.5 times/sec, FAST: Approx. 50 times/sec |
Max. input voltage: |
50mV to 5V range ± 800V (continuous)
50V to 1000V range ± 1100V (continuous) |
Resolution and noise rejection |
Resolution |
Sample Rate |
NMRR |
CMRR |
5.5-digit |
SLOW |
55dB or more |
120dB or more |
5.5-digit |
MID |
55dB or more |
120dB or more |
4.5-digit |
FAST |
0dB |
55dB or more |
|
|
3. CH-B DC Volt (DCV) VOAC7523/7520 only |
|
Range |
Resolution |
Input Resistance |
Accuracy* |
4.5-digit |
SLOW/MID |
FAST |
5V |
100µV |
CH-B:H to CH-B:L 10MW ± 3%
CH-B:H to CH-A:L 5MW ± 3%
CH-B:L to CH-A:L 5MW ± 3% |
0.025+2 |
0.025+30 |
50V |
1mV |
0.025+8 |
300V |
10mV |
0.025+5 |
|
Max. input voltage: |
± 300V between CH-A L and CH-B ± 300V |
Resolution and noise rejection |
Resolution |
Sample Rate |
NMRR |
CMRR |
Isolation between CH-A and CH-B |
4.5-digit |
SLOW/MID |
55dB or more |
120dB or more |
56dB or more |
4.5-digit |
FAST |
0dB |
55dB or more |
|
|
4. AC Volt (ACV, DC+ACV) detection of True RMS
Up to 100kHz for VOAC7520/7521A |
|
Range |
Resolution |
Measurement Range |
Input Resistance |
5.5-digit |
SLOW |
MID/FAST |
500mV |
1µV |
15Hz to 300kHz |
200Hz to 300kHz |
less than approx.
1MW // 100pF |
5V |
10µV |
50V |
100µV |
500V |
1mV |
45Hz to 100kHz |
200Hz to 100kHz |
750V |
1mV |
45Hz to 20kHz |
200Hz to 20kHz |
|
Accuracy: SLOW Sample (Sine wave) |
Frequency |
Accuracy* |
15Hz to 45Hz |
0.5+150 |
45Hz to 100Hz |
0.25+150 |
100Hz to 30kHz |
0.2+150 |
30kHz to 100kHz |
0.5+300 |
100kHz to 300kHz |
2.5+1000 |
|
Coefficient to input other than sine wave |
Crest Factor |
Frequency |
1 to 1.5 |
1.5 to 2 |
2 to 3 |
15Hz to 30kHz |
0.05% |
0.15% |
0.30% |
30kHz to 300kHz |
0.20% |
- |
- |
|
Sample Rate |
Resolution |
Reading Rate |
Response Time |
SLOW |
5.5-digit |
4 times/sec |
less than 3 sec |
MID/FAST |
5.5-digit |
20 times/sec |
less than 2 sec |
|
Max. input voltage: 780Vrms, ± 1100V DC (continuous) |
In the case of DC+ACV, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy digit. |
Sample rate of FAST becomes the same values as MID (approx. 20 times/sec). |
|
5. DC Current (DCA) |
|
Range |
Resolution |
Accuracy* |
Input Resistance |
5.5-digit |
4.5-digit |
SLOW/MID |
FAST |
5mA |
10nA |
100nA |
0.05+7 |
0.05+17 |
less than 150W |
50mA |
100nA |
1µA |
less than 15W |
500mA |
1µA |
10µA |
less than 2W |
10A |
100µA |
1mA |
0.2+7 |
0.2+17 |
less than 0.1W |
|
Auto range is not available at 5mA to 500mA range and 10A range because of using different input terminals. |
Max. input current: |
5mA to 500mA range 500mA (FUSE 0.5A/250V)
10A range 10A (FUSE 15A/250V) |
|
6. AC Current (ACA, DC+ACA) |
|
Range |
Resolution |
Measurement Range |
Input Resistance |
5.5-digit |
SLOW/MID |
FAST |
5mA |
10nA |
15Hz to 5kHz |
200Hz to 5kHz |
less than 150W |
50mA |
100nA |
less than 15W |
500mA |
1µA |
45Hz to 5kHz |
less than 2W |
10A |
100µA |
less than 0.1W |
|
Accuracy: SLOW Sample (Sine wave) 5% or more against the range |
Frequency |
Accuracy* |
Crest Factor |
1 to 1.5 |
1.5 to 2 |
2 to 3 |
15Hz to 45Hz |
1+200 |
0.05% |
0.15% |
0.30% |
45Hz to 1kHz |
0.4+200 |
1kHz to 5kHz |
5.0+200 |
|
Sample Rate |
Resolution |
Reading Range |
Response time |
SLOW |
5.5-digit |
4 times/sec |
less than 3 sec |
MID/FAST |
5.5-digit |
20 times/sec |
less than 2 sec |
|
Max. input current: |
5mA to 500mA range 500mA (FUSE 0.5A)
10A range 10A (FUSE 15A) |
DC Component on input current must be included in the Max. input current. |
In the case of 10A range at 45Hz to 1kHz, 0.3 must be added to %. |
In the case of DC+ACA, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy digit. |
Sample rate of FAST becomes the same value as MID (approx. 20 times/sec). |
|
7. Resistance (2 WireW/4 WireW) 4 WireW: VOAC7522/7521A only |
|
Range |
Resolution |
Accuracy* |
Test Current |
SLOW/MID |
FAST |
SLOW/MID |
FAST |
50W |
0.1mW |
1mW |
0.025+10 |
0.025+15 |
approx. 10mA |
500W |
1mW |
10mW |
0.014+3 |
0.014+8 |
approx. 10mA |
5kW |
10mW |
0.1W |
approx. 1mA |
50kW |
0.1W |
1W |
approx. 100µA |
500kW |
1W |
10W |
0.015+3 |
0.015+33 |
approx. 10µA |
5MW |
10W |
10W |
0.033+30 |
0.033+30 |
approx. 1µA |
50MW |
100W |
100W |
0.25+30 |
0.25+30 |
approx. 100nA |
500MW |
1kW |
1kW |
1.5+50 |
1.5+50 |
approx. 10nA |
|
Max. input voltage: ± 500V peak |
Open circuit test voltage: less than 12V |
The accuracy at 50W to 5kW range are specified after zero compensation through the REL operation. |
Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec). |
|
8. Low-Power Resistance (2 WireW) |
|
Range |
Resolution |
Accuracy* |
Test Current |
SLOW/MID/FAST |
SLOW/MID |
FAST |
500W |
10mW |
0.1+5 |
0.1+15 |
approx. 1mA |
5kW |
0.1W |
approx. 100µA |
50kW |
1W |
approx. 10µA |
500kW |
10W |
0.2+30 |
0.2+40 |
approx. 1µA |
5MW |
100W |
0.2+30 |
approx. 100nA |
50MW |
1kW |
1.5+30 |
1.5+30 |
approx. 10nA |
|
Max. input voltage: ± 500V peak |
Open circuit test voltage: less than 12V |
The accuracy at 500W to 5kW range are specified after zero compensation through the REL operation. |
Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec). |
Indications are in 4.5 digits for SLOW, MID, and FAST. |
|
9. Diode |
|
Test Current |
Measurement Range |
Accuracy* |
Open Circuit Test Voltave |
Max. Input Voltave |
approx. 1mA or 10mA |
0.1mV to 5.0999V |
0.014+13 |
less than 12V |
± 500V peak |
|
|
10. Temperature |
|
Thermocouple |
Temperature Range to be Measured |
Accuracy* |
Resolution |
Max. Input Voltave |
R |
-50 to 0°C |
0.2+70 |
0.1°C |
± 500V peak |
0 to +100°C |
0.2+50 |
+100 to +1768°C |
0.2+30 |
K(CA) |
-270 to -100°C |
0.15+50 |
-100 to 0°C |
0.15+35 |
0 to +1372°C |
0.15+20 |
T(CC) |
-270 to -100°C |
0.15+50 |
-100 to 0°C |
0.15+35 |
0 to +400°C |
0.15+20 |
J(IC) |
-210 to -100°C |
0.15+50 |
-100 to 0°C |
0.15+35 |
0 to +1200°C |
0.15+20 |
E(CRC) |
-270 to -100°C |
0.15+50 |
-100 to 0°C |
0.15+35 |
0 to +1000°C |
0.15+20 |
|
The above accuracy values do not include the thermocouple accuracy.
±0.1°C/°C is added (for all thermocouples) with the operating ambient temperature of this product at 0°C to 18°C and 28°C to 50°C.
±0.3°C/°C is added (for all thermocouples) in the temperature range to be measured at -200°C or lower.
The reference thermo electric force is calculated by the broken line approximation according to JIS C 1602-1995.
If this product and the thermocouple are connected via a plug, an error for contact temperature compensation is added. |
|
11. Frequency (AC couple, Crest Factor: less than 3) |
|
|
|