安規測試器

TOS5000
Withstanding Voltage Tester

The TOS5000 Series consist of various types of withstanding voltage testers
In addition to the use of a zero turn-on switch and the providing of useful functions giving consideration to anti-noise measures, automation and conservation of manpower



TOS5052
Withstanding Voltage TesterEquipped with rise-time control function

0.50kV to 5kV AC, 500VA (100mA)
Cutoff current setting range : 0.1 to 110mA
Rise-time control function provided
Frequency: 50 or 60 Hz selectable



TOS9200/9201AC 5kV/ DC6kV, W/I Tester

Fully programmable (GPIB/RS-232C)
High-power design (AC 5 kV, 100 mA, over 200 mA in short-circuiting the output)
A rise-time and fall-time control function (AC withstanding voltage testing)
A discharge function (after DC withstanding voltage and insulation resistance testing)
Setting of up to 16 channels realized by a high-voltage scanner (TOS9221/TOS9220)
Read back of measurement data



TOS8870AAC5kV, W/I Tester

Withstanding voltage test and insulation test can be performed automatically
Output: 0 to 5kV, 100mA at puncture test
Voltmeter : JIS class 1, Accuracy : ±1.5% f.s
Remote control available in test/reset mode
500V/1000M Ohm or 1000V/2000M Ohm in 2 ranges for insulation test



TOS8850AAC5kV, W/I Tester

Withstanding voltage test and insulation test can be performed automatically
Output: 0 to 5kV, 100mA at puncture test
Remote control available in test/reset mode
500V/1000M Ohm or 1000V/2000M Ohm in 2 ranges for insulation test



TOS6200Earth Continuity Tester

Test current value: 3 to 30 A AC /
Resistance value: 0.001 to 1.200 Ohm
Compact, lightweight, and constant current
Stores 100 test conditions in memory
Incorporates test conditions into program
Contact check function
Equipped with GPIB and RS-232C interfaces as standard



TOS7200 Insulation Tester

Output voltage setting range: -25 to -1000V
Resistance measurement range: 0.01 M Ohm to 5000 M Ohm
Equipped with a window comparator, discharge function, and hold function (which holds the measured resistance at the end of testing while PASS judgment is being output).
Provided with the SIGNAL I/O connector and remote control terminal
Equipped with the RS-232C interface as standard.



Options for Electrical Safety Testers

Remote control box
High-voltage test probe
High-voltage test Lead
High-voltage shielded cable
Warning light unit / Buzzer unit
Test probe for Earth Continuity Tester
Test lead for Earth Continuity Tester
Deflection factor and attenuator compensation (maxuimum output voltage : 100V, square-wave : 1kHz)